Many AiT products are available to Mil Std 883D as well as NASA & ESA outgassing qualification standards. Materials can be supplied in one or two part components, syringe, in pre-formed films, sheets in various sizes and in jars.
A list of products from AIT that has years of proven success in NASA and ESA outgassing compliant adhesives for space applications.
NASA-ESA OUTGASSING QUALIFIED PRODUCTS Test Procedures: ESA: PSS-01-792; NASA: ASTM E595-90 Test Conditions: 125OC for 24 hours @ 10-3 Pa (<10-5 Torr) Acceptability: Total Weight Loss (TWL)<1% Volatile Condensible Materials (VCM) <0.1% Water Vapour Regained (WVR) NR
(Click on the Product for the TDS.)
AIT Product
|
%TWL
|
%VCM
|
%WVR
|
EG8050Cured at 100OC @ 5 min.)
|
0.57
|
0.016
|
0.21
|
EG8050-HC(Cured at 150OC @ 5 min.)
|
0.84
|
0.070
|
0.64
|
ESP8350(Cured at 150OC @ 16 hr.)
|
0.08
|
0.010
|
0.01
|
ME7155(Cured at 150OC @ 5 min.)
|
0.54
|
0.067
|
Not reported
|
ME7158(Cured at 150OC @ 16 hr.)
|
0.28
|
0.053
|
Not reported
|
ME7158(Cured at 125OC @ 24 hr.)
|
0.30
|
0.045
|
Not reported
|
ME7158(Cured at 100OC @ 4 hr.)
|
0.51
|
0.100
|
Not reported
|
ME7159(Cured at 150OC @ 16 hr.)
|
0.23
|
0.031
|
Not reported
|
ME7159(Cured at 150OC @ 24 hr.)
|
0.27
|
0.040
|
Not reported
|
ME7159(Cured at 150OC @ 4 hr.)
|
0.58
|
0.090
|
Not reported
|
ME8456(Cured at 100OC @ 5 hr.)
|
0.25
|
0.050
|
0.05
|
TC8750(Cured at 150OC @ 30 min.)
|
< >0.28
|
0.070
|
0.06
|
TP7205(Post bonding baked at 150OC @ 30 min.)
|
0.78
|
0.080
|
0.08
|
TP7209(None)
|
0.38
|
0.080
|
0.28
|
TP7758(Post bonding baked at 150OC @ 30 min.)
|
0.38
|
0.060
|
0.06
|
TP7759(Post bonding baked at 250OC @ 0.5
sec.)
|
0.25
|
0.010
|
0.23
|